42
4242
42
Fire alarm, zone alarm 1~4, unknown user, expired user, invalid user, user PIN fail, invalid time
zone, system PIN fail, ARM PIN fail, door forced open, door held open, and remote alarm.
All these events can be allocated to any alarm output. Note the built-in buzzer will beep
when any alarm output is triggered for any reason. The detailed configuration method is
introduced in the following section.
Enter Alarm Setting Menu
Under System menu, press three times to bring up the following window:
Press to enter Alarm Setting menu. Use and to choose from different menu
options. All menu options under Alarm Setting are introduced below:
Fire Alarm
For correspondence between fire alarm and doors, please refer to “Set Door Control at Fire
Alarm” in this chapter. In case of fire alarm input, controller will generate fire alarm output
according to this setting. By default, both alarm outputs are active per Fire Alarm event. At the
following submenu:
Press the 1-2 numeric key to toggle between Y/N for corresponding alarm output. Y means
the alarm output in enabled. N means the alarm output is disabled.
Note: The above procedure to set Y/N for alarm outputs are the same for the rest of
the following submenus.
SYS PIN Fail
Please refer to section “Set System P” in this chapter to know how to set system PIN. A SYS
PIN Fail event will be generated when user enters the PIN to enter system setting and a wrong
PIN is entered three times consecutively.
Use steps outlined in “Fire Alarm” submenu to change settings.
SYS PIN Fail
SYS PIN FailSYS PIN Fail
SYS PIN Fail
NN
NNNN
NN
Fire Alarm
Fire AlarmFire Alarm
Fire Alarm
YY
YYYY
YY
Alarm Setting
Alarm SettingAlarm Setting
Alarm Setting