NAV IP Access controller
46
or multiple alarm outputs. Alarm components, configuration basics, and menu settings are introduced
below.
5.9.1ComponentsforAlarm
NAV Controller consists of two basic components: one main module and one door module. Users can
additionallyinstallthreemoredoormodulesandonealarmmodule.
Thesethreetypesofmodulesareallequippedwithalarmfunction.Themainmodulehas2alarminputs
and2alarmoutputs,calledMainAlarm
OutputandAuxiliaryAlarmOutputrespectively.
Eachdoormodulehas2alarmoutputs,whichusuallyreacttoalarmeventsonthecorrespondingdoor.
However, it can be set to react to other alarm events as well. Alarm outputs on the door module can
connectupto5Aexternalalarmdevices.
Thealarmmodulehas8alarminputsand8alarmoutputs.8alarminputscanconnecttoexternalalarm
input devices, such as PIR motion sensor, glass sensor and etc. 8 alarm outputs can connect up to 2A
externalalarmdevices.
Theabovementionedarephysicaldevicesprovidingalarmfunctions
User
can freely define the allocation of any input to any output. The following section outlines basic
conceptsforevents,alarmandconfiguration.
5.9.2AlarmConfigurationBasics
NAVControllerkeepstrackofalleventsintheaccesscontrolsystem,eitherlegalorillegal,eithernormal
orabnormal.Forexample,accessgranted,accessdeniedandsoon.
Someeventsare criticalwhichmusttriggerthe alarmoutput,likethefirm alarminput,thezonealarm
inputandetc.Butsomeeventsarenotthatimportanttotriggerthealarmoutput,likethedeniedaccess
duetotheinvalidtime.Thesesettingsalldependontheusers’requirements.NAVControllercollectsall
eventsthatmighttriggerthealarmoutputandprovidesthefullcapacitytoenableordisablethealarm
outputontheseevents.
Sometimes user wants to allocate a particular event to a particular alarm output, or allocate alarm
inputs in certain area to multiple alarm outputs. NAV Controller delivers all the function and flexibility
userneed.Usercandefinewhethercertaineventwilltriggeranalarm,andcanfurther
specifytowhich
alarmoutputthateventisallocated.
Alleventsthatmighttriggeranalarmarelistedbelow:
Alarminput0~9,unknowncard,expiredcard,invalidcard,invaliddoor,invalidtime,cardanti‐passback
fail,cardPINfail,SYSPINfail,ARMPINfail,doorforcedopen,door
heldopen,readerlost, andremote
alarm.
All these events can be allocated to any alarm relay output on main module, door module, and alarm
module.Thedetailedconfigurationmethodisintroducedinthefollowingsection.
5.9.3EnterAlarmSettingMenu
UnderSystemmenu,press fourtimestobringupthefollowingwindow:
Kommentare zu diesen Handbüchern