15
3.1. The pin assignment of the 9 pin D-SUB connector
PIN # NAME PIN # NAME
1 NOT CONNECTED 1 NOT CONNECTED
2 TXD 2 RXD
3 RXD 3 TXD
4 NOT CONNECTED 4 DTR
5 GROUND 5 GROUND
6 NOT CONNECTED 6 DSR
7 NOT CONNECTED 7 RTS
8 NOT CONNECTED 8 CTS
9 NOT CONNECTED 9 NOT CONNECTED
EverPlex 8CQ
HOST
3.2. Transmission Setting
The transmission setting in EverPlex 8CQ is 9600 baud rate, 1 start bit, 1 stop bit and no parity
3.3. Remote control protocol
A computer or a terminal can be used to control the EverPlex 8CQ by sending two-character
ASCII command through RS232 connector, these ASCII commands are started with 'K' or 'k'.
there are 9 ASCII commands mapped to the 9 keypads in the front panel and 1 additional
commands to reset the EverPlex 8CQ to the QUAD A display state. these 10 ASCII commands are:
EverPlex 8CQ Remote Control Command Table
ASCII CODE FUNCTION Keypad in front panel
K1 Full Screen 1
K2 Full Screen 2
K3 Full Screen 3
K4 Full Screen 4
K5 PAGE A A
K6 PAGE B B
K7 Sequential Switching SEQ
K8 VCR Play Back
K9 SET SET
K0 Reset EverPlex 8CQ to Quad display none
EverFocus Electronics Corp.
Kommentare zu diesen Handbüchern