EverFocus EDSR100H Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Digitale Videorecorder (DVR) EverFocus EDSR100H herunter. EverFocus EDSR100H Technical data Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - DVR and Telemetry Keyboard

EKB500 DVR and Telemetry Keyboard FW 1.5New operating concept !

Seite 2 - 1 SAFETY WARNINGS

EKB500_ma_en_rev1 5_3 105.2 EPTZ 500 / 1000 / 3000 / 3500 SPEED DOME CAMERA CONNECTION Applied protocol type: EVF2 (standard) 5.3 ED-2200, ED-

Seite 3 - TABLE OF CONTENTS

EKB500_ma_en_rev1 5_3 115.4 CONNECTION OF PELCO-D / -P PROTOCOL-COMPATIBLE DEVICES Basic functions of speed domes and telemetry rece

Seite 4 - 2 INTRODUCTION

EKB500_ma_en_rev1 5_3 125.5 EVERFOCUS DVR CONNECTION The EKB 500 keyboard can control the following digital video recorders: EDSR series (despite E

Seite 5 - 2.4 DELIVERY SCOPE

EKB500_ma_en_rev1 5_3 13 System settings required for start-up: Required system settings for DVR control: DVR: MENU > RS232/RS485:

Seite 6 - 3 OPERATING ELEMENTS

EKB500_ma_en_rev1 5_3 14Keyboard Version 1.5 5.6 CONNECTION OF SEVERAL KEYBOARDS If several keyboards (max. 8) are used in a system, the RS-485 bu

Seite 7 - 4 KEYBOARD CONNECTORS

EKB500_ma_en_rev1 5_3 15COM Port Setting Device Setting 6 MENU SETTINGS After electrical installation and start-up, both the connected devices and

Seite 8 - WRONG !

EKB500_ma_en_rev1 5_3 16 6.2 COM PORT SETTING - RS-485 INTERFACE SETTING Define telemetry protocol type and transmission rate in this menu. MMMEE

Seite 9 - EKB500_ma_en_rev1 5_3 9

EKB500_ma_en_rev1 5_3 17Monitor Name : _ _ _ Video Connected to DVR : _ _ _ Mon : _ _ Video Connected to DVR : _ _ _ CH : _ _ Monitor : 1__ c

Seite 10 - CONNECTION

EKB500_ma_en_rev1 5_3 18Total 005 Cameras [ ENT ] to view list Name RS485 DVR CH 012 2- 014 002 03 <DVR Name : _ _ _ RS485

Seite 11 - EKB500_ma_en_rev1 5_3 11

EKB500_ma_en_rev1 5_3 19Total 005 Monitors [ ENT ] to view list Name DVR Mon 005 004 02 < Name RS485 004 1- 023

Seite 12 - EKB500_ma_en_rev1 5_3 12

EKB500_ma_en_rev1 5_3 21 SAFETY WARNINGS • Do not place the device near to heaters, furnaces, other heat sources or under direct solar irradiation.

Seite 13 - EKB500_ma_en_rev1 5_3 13

EKB500_ma_en_rev1 5_3 20This keyboard ID : 0 ( 0 – 7 , 0 for master ) Input new Password : _ _ _ _ _ _ _ _ Repeat Password : _ _ _ _ _ _ _ _ Protec

Seite 14 - 5.7 START-UP

EKB500_ma_en_rev1 5_3 21Release Joystick and press [ ENT ] Move joystick to corners. X+000 Y+000 Z+000 X-000 Y- OK Z-000 Buzzer

Seite 15 - 6 MENU SETTINGS

EKB500_ma_en_rev1 5_3 22[ _ _ _ _ _ _ _ _ _ ] Pressed[ Esc ] to exit Shuttle : >>>> 5 Jog : 9934 Load default setting P

Seite 16 - 6.3 DEVICE SETTING

EKB500_ma_en_rev1 5_3 23CAM - 001 MON - 01 ___ [ CAM / MON ] CAM - 001 MON - 04 > DVR ___ [ CAM / MON ] CAM - 001 MON - 01

Seite 17 - EKB500_ma_en_rev1 5_3 17

EKB500_ma_en_rev1 5_3 24CAM - 001 MON - 01 > DVR ___ [ CAM / MON ] 7.4 DVR PASSWORD INPUT If password protection is active in DVR, then t

Seite 18 - 6.3.3 DVR Setting

EKB500_ma_en_rev1 5_3 25The essential functions are described below; for further details please refer to the DVR manual. Please note that this descri

Seite 19 - <

EKB500_ma_en_rev1 5_3 267.6 PTZ OPERATION / SETUP The operation of speed domes and telemetry receivers requires the setup of these devices in the E

Seite 20 - 6.4 KEYBOARD SETTING

EKB500_ma_en_rev1 5_3 27CAM : 0001 MON : 0001 [ CAM / MON / DVR ] 7.6.1 EverFocus EPTZ series The following functions are available after camer

Seite 21 - 6.4.5 Joystick calibration

EKB500_ma_en_rev1 5_3 287.6.1.1 EPTZ on-screen display Start EPTZ menu: If DVR Main monitor is selected ("DVR" in LCD - display):

Seite 22 - EKB500_ma_en_rev1 5_3 22

EKB500_ma_en_rev1 5_3 29Back to home if no action for ___Minute Move to home position [ENT] to confirm Auto Back Enabled [↑↓] to toggle Speed:___[1-2

Seite 23 - 7 OPERATION

EKB500_ma_en_rev1 5_3 3TABLE OF CONTENTS 1 SAFETY WARNINGS ...

Seite 24 - 7.4 DVR PASSWORD INPUT

EKB500_ma_en_rev1 5_3 307.6.1.5 Preset tours The EPTZ series supports up to 16 programmable preset tours with up to 16 presets each. For these tour

Seite 25 - Function Keys / operation

EKB500_ma_en_rev1 5_3 31Link Alarm:_ [1-4] to Position [↑↓]:___ Link Alarm:_ [1-4] to Tour [↑↓]:___ Del AlarmLink:_[1-4] [ENT] to confirm 7.6.1.6

Seite 26 - 7.6 PTZ OPERATION / SETUP

EKB500_ma_en_rev1 5_3 327.6.2 EverFocus ED 2200/2250, Samsung El. SCC-641/643/6405 operation Required protocol type in "COM PORT SETTINGS"

Seite 27 - EKB500_ma_en_rev1 5_3 27

EKB500_ma_en_rev1 5_3 33Speed:___[1-239] [ENT] to start. 7.6.2.4 Autopan End stop definition Define both the end stops and the autopan speed in the

Seite 28 - 7.6.1.2 Positions (presets)

EKB500_ma_en_rev1 5_3 34Speed:___[1-239] [ENT] to start. 7.6.3.2 Presets Save presets SSSHHHIIIFFFTTT (hold) + PPPOOOSSSIIITTTIIIOOONNN > enter

Seite 29 - 7.6.1.4 Autopan

EKB500_ma_en_rev1 5_3 357.6.3.5 Pattern / Preset Tour Define patterns, which also can contain a preset tour, in the speed dome’s on-screen display. F

Seite 30 - 7.6.1.5 Preset tours

EKB500_ma_en_rev1 5_3 368 SPECIFICATIONS Keys 48 Joystick 3-axis Display 2 lines with 20 characters each RS-485 2 independent RS-485 ports with 2

Seite 31 - EKB500_ma_en_rev1 5_3 31

EKB500_ma_en_rev1 5_3 379 APPENDIX A: FACTORY SETTINGS PORT settings: Port 1: 9600 baud, EverFocus Port 2: 9600 baud, EverFocus DEVICE SETTINGS / D

Seite 32 - 7.6.2.3 Home position

EKB500_ma_en_rev1 5_3 38 Cam49: connected to DVR4, input1, PTZ-ID: OFF ... Cam64: connected to DVR4, input16, PTZ-ID: OFF Cam65: connected to DVR

Seite 33 - 7.6.3.1 On-screen display

EKB500_ma_en_rev1 5_3 39 EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwa

Seite 34 - 7.6.3.3 Autopan

EKB500_ma_en_rev1 5_3 42 INTRODUCTION The EKB 500 universal keyboard was developed for both DVR remote control and telemetry control of speed domes

Seite 35 - EKB500_ma_en_rev1 5_3 35

EKB500_ma_en_rev1 5_3 52.4 DELIVERY SCOPE 1 x EKB-500 universal keyboard 1 x 12 VDC power supply 1 x RJ-45 connector, 120 Ohm terminated 1 x RS-485

Seite 36 - 8 SPECIFICATIONS

EKB500_ma_en_rev1 5_3 63 OPERATING ELEMENTS 1. DVR, MON, CAM Operation mode toggle key: DDDVVVRRR: from firmware version 1.5

Seite 37 - EKB500_ma_en_rev1 5_3 37

EKB500_ma_en_rev1 5_3 74 KEYBOARD CONNECTORS 4.1 RS-485 PORTS EKB-500 provides two independent RS-485 ports with 2 RJ-45 plugs each (loop-through).

Seite 38 - BUZZER: ON

EKB500_ma_en_rev1 5_3 85 INSTALLATION 5.1 GENERAL RS-485 BUS INSTALLATION EKB 500 uses an RS-485 simplex wiring; the signal is transferred via a

Seite 39 - EverFocus Electronics Corp

EKB500_ma_en_rev1 5_3 9 In case the maximum number of 32 bus participants is exceeded, the number of connected devices can be increased by u

Kommentare zu diesen Handbüchern

Keine Kommentare